• Studio degli effetti della mordenzatura con acido fluoridrico sul disilicato di litio utilizzato in odontoiatria
  • Effects of hydrofluoric acid etching on lithium disilicate in dentistry
  • Iorizzo, Ginevra Maria <1982>

Subject

  • ING-IND/22 Scienza e tecnologia dei materiali

Description

  • Scopo dello studio: valutare i cambiamenti indotti da diversi trattamenti di mordenzatura sulla morfologia superficiale e sulla microstruttura di due vetro-ceramiche a base disilicato di litio (IPS e.max® Press e IPS e.max® CAD) ed esaminarne gli effetti sia sull’adesione con un cemento resinoso che sulla resistenza alla flessione. Materiali e metodi: Settanta dischetti (12 mm di diametro, 2 mm di spessore) di ogni ceramica sono stati preparati e divisi in 5 gruppi: nessun trattamento (G1), HF 5% 20s (G2), HF 5% 60s (G3), HF 9.6% 20s (G4), HF 9.6% 60s (G5). Un campione per ogni gruppo è stato analizzato mediante profilometro ottico e osservato al SEM. Per gli altri campioni è stato determinato lo shear bond strength (SBS) con un cemento resinoso. Dopo l’SBS test, i campioni sono stati caricati fino a frattura utilizzando il piston-on-three-ball test per determinarne la resistenza biassiale alla flessione. Risultati: L’analisi morfologica e microstrutturale dei campioni ha rivelato come diversi trattamenti di mordenzatura producano delle modifiche nella rugosità superficiale che non sono direttamente collegate ad un aumento dei valori di adesione e dei cambiamenti microstrutturali che sono più rilevanti con l’aumento del tempo di mordenzatura e di concentrazione dell’acido. I valori medi di adesione (MPa) per IPS e.max® CAD sono significativamente più alti in G2 e G3 (21,28 +/- 4,9 e 19,55 +/- 5,41 rispettivamente); per IPS e.max® Press, i valori più elevati sono in G3 (16,80 +/- 3,96). La resistenza biassiale alla flessione media (MPa) è più alta in IPS e.max® CAD (695 +/- 161) che in IPS e.max® Press (588 +/- 117), ma non è non influenzata dalla mordenzatura con HF. Conclusioni: il disilicato di litio va mordenzato preferibilmente con HF al 5%. La mordenzatura produce alcuni cambiamenti superficiali e microstrutturali nel materiale, ma tali cambiamenti non ne influenzano la resistenza in flessione.
  • Purpose: The aim of this study was to evaluate the changes induced by different etching treatments on the surface morphology and microstructure of two lithium disilicate-based glass ceramic (IPS e.max® Press and IPS e.max® CAD) and examine the effects on the bond strength between ceramic and composite resin and on the biaxial flexural strength. Materials and methods: Seventy discs (12 mm diameter, 2 mm thickness) of each ceramic were prepared and divided in 5 groups: no treatment (G1), HF 5% 20s (G2), HF 5% 60s (G3), HF 9.6% 20s (G4), HF 9.6% 60s (G5). One specimen for each group was examined by optical profilometer and observed under scanning electron microscopy. On the other specimens was determined the shear bond strength (SBS) with a resin cement. After SBS test, specimens were loaded to failure using a piston-on-three-ball test to determine the biaxial flexural strength. Results: morphological analysis of treated specimens showed that different etching treatments produces changes in surface roughness but this changes are not directly related to an increasing adhesion value. The SEM analysis revealed that etching causes microstructural changes in lithium disilicate which are more relevant with the increasing of etching time and acid concentration. The mean bond strength values (MPa) for IPS e.max® CAD are statistically higher in G2 and G3 (21,28 +/- 4,9 and 19,55 +/- 5,41 respectively); for IPS e.max® Press, G3 has significant higher adhesion value (16,80 +/- 3,96). The mean biaxial flexural strength values (MPa) are significantly higher in IPS e.max® CAD (695 +/- 161) than in IPS e.max® Press (588 +/- 117). Etching with HF does not affect the flexural strength of the material. Conclusions: lithium disilicate has to be etched preferably with 5% HF. Etching produces several changes in surface and microstructure of the material, but does not compromise the flexural strength.

Date

  • 2014-05-23

Type

  • Doctoral Thesis
  • PeerReviewed

Format

  • application/pdf

Identifier

urn:nbn:it:unibo-12947

Iorizzo, Ginevra Maria (2014) Studio degli effetti della mordenzatura con acido fluoridrico sul disilicato di litio utilizzato in odontoiatria, [Dissertation thesis], Alma Mater Studiorum Università di Bologna. Dottorato di ricerca in Ingegneria dei materiali , 25 Ciclo. DOI 10.6092/unibo/amsdottorato/6571.