• Correlazione anatomo funzionale tra analisi cinematica intraoperatoria passiva con navigatore e analisi cinematica post-operatoria con tecnica RSA dinamica sotto carico del ginocchio protesizzato
  • Anatomical and functional correlation between intra-operative passive kinematics assesment and postoperative kinematics with dynamic RSA under weight-bearing of the knee prosthesis
  • Nitri, Marco <1981>

Subject

  • MED/33 Malattie apparato locomotore

Description

  • Lo studio della cinematica articolare del ginocchio protesizzato, a distanza di più di 70 anni dai primi interventi di artroprotesi dell’articolazione, rappresenta, ancora oggi, un campo di ricerca di estremo interesse ed in continua evoluzione e valutazione sia dal punto di vista ortopedico che ingegneristico. Diverse tecniche sono descritte in letteratura per valutare la biomeccanica della protesi come la chirurgia assistita da navigatore, ma la recente tecnologia “RSA”, sviluppata nel 1972 a Lund (Svezia), risulta la più accurata. Nella seguente dissertazione, redatta in collaborazione con il gruppo di ricerca del Laboratorio di Biomeccanica e Innovazione Tecnologica dell’Istituto Ortopedico Rizzoli di Bologna e dall’Università di Bologna, è stato studiata, in vivo e sotto carico, la cinetica articolare del ginocchio protesizzato attraverso il suo studio cinematico intraoperatorio mediante navigatore e post-operatorio mediante tecnica RSA a 2,5 anni di follow up. Il protocollo di studio comprendeva una valutazione cinematica intraoperatoria, un valutazione clinica ed una valutazione radiologica post-operatoria tramite tecnica RSA dinamica effettuata presso gli ambulatori dell’Istituto Ortopedico Rizzoli di Bologna. La valutazione intraoperatoria è stata effettuata utilizzando un sistema di chirurgia navigata, la valutazione clinica, composta da un esame obiettivo ortopedico ed un questionario, ha permesso di ottenere dati utili alla costruzione di score quali Knee Society Score clinico (KSSc), Knee Society Score funzionale (KSSf) e VAS ed infine la valutazione radiografica post-peratoria è stata condotta mediante l’utilizzo di un macchinario per RSA dinamica e si è avvalsa di un software dedicato. Scopo dello studio è stato quello di analizzare la cinematica intra operatoria mediante il sistema di navigazione e la cinematica post-operatoria mediante tecnica di RSA dinamica durante l’esecuzione di comuni task motori quali discesa di uno scalino, alzata dalla sedia e passo e di correlare i dati intraoperatori con quelli post-operatori ottenuti.
  • The study of the joint kinematics of the knee prosthesis, after more than 70 years from the first measures of joint arthroplasty, is still today a very interesting research field in continuous evolution and evaluation both from an orthopedic and engineering point of view. Several techniques are described in the literature to evaluate the biomechanics of the prosthesis as a navigator assisted surgery, but the recent "RSA" technology, developed in 1972 in Lund (Sweden), is the most accurate. In the following essay, written in collaboration with the research group of the Laboratory of Biomechanics and Innovation Technological Rizzoli Orthopaedic Institute of Bologna and the University of Bologna, he has been studied in vivo and under load, the prosthetic knee joint kinetics through its kinematic study using intraoperative navigation system and postoperative using RSA technique to 2.5 years of follow up. The study protocol included a kinematics intraoperative assessment, a clinical evaluation and postoperative radiographic evaluation performed by RSA dynamic technique at the clinics Rizzoli Orthopaedic Institute of Bologna. The intraoperative evaluation was performed using a navigated surgery system, clinical assessment, consisting of an orthopedic physical examination and a questionnaire, it has resulted in data useful to the construction of a clinical score as Knee Society Score (KSSC), functional Knee Society Score (KSSf) and VAS and finally the post-postoperative radiographic evaluation it was conducted through the use of a machine for RSA dynamic and has made use of a dedicated software. Aim of the study was to analyze the kinematic operating intra using the navigation system and the postoperative kinematics using RSA dynamic technique when performing common tasks such engines descent stepped, got up from the chair and step and to correlate intraoperative data with post-operative obtained.

Date

  • 2016-04-19

Type

  • Doctoral Thesis
  • PeerReviewed

Format

  • application/pdf

Identifier

urn:nbn:it:unibo-18480

Nitri, Marco (2016) Correlazione anatomo funzionale tra analisi cinematica intraoperatoria passiva con navigatore e analisi cinematica post-operatoria con tecnica RSA dinamica sotto carico del ginocchio protesizzato, [Dissertation thesis], Alma Mater Studiorum Università di Bologna. Dottorato di ricerca in Scienze farmacologiche e tossicologiche, dello sviluppo e del movimento umano , 28 Ciclo. DOI 10.6092/unibo/amsdottorato/7595.

Relations